Enter your product and environment information to create an Installation and Upgrade checklist.
Product:
Product version you are installing or upgrading to:
Platform:
Processor:
Product version you are upgrading from (optional):

 

Custom Reports Using Data Collectors

Installation and Upgrade Checklist Report for InfoScale Foundation 7.0, Windows Server 2012 R2, x86-64
Provide your feedback about this report to help us imporove it.
Rating this report:
Enter your email address:
What sections in this report are useful? or what sections in this report are not useful?

What improvements do you want to include in this report?

Type the numbers in the picture:  
View Control
Use "Collapse all" to hide all sections, or "Expand all" to show all sections. Collapse all
  
Back to top

Components for InfoScale

The InfoScale product you selected contains the following component(s).
  • Dynamic Multi-Pathing
  • Storage Foundation Basic
Get more introduction of Veritas InfoScale.
  
Back to top

System requirements

Required number of CPUs: 1
Recommended speed of CPUs: 1GHz AMD Opteron, AMD Athlon 64, Intel Xeon with Intel EM64T support, Intel Pentium IV with EM64T support processor or faster.
Required memory: 1GB of RAM
Required disk space:
    Installation options Required disk space
    InfoScale Foundation 125 MB
  
Back to top

Patches for InfoScale Foundation and Platform

Product (recommended)
Patch Date Size
infoscale-win_x64-7.0.17001.129 2018-11-19 649.16 KB
infoscale-win_x64-7.0.17002.129 2018-11-19 678.65 KB
infoscale-win_x...5303_129_3866918 2017-05-15 10.88 MB
infoscale-win_x64-7.0.1 2015-12-14 70.51 MB
Platform (required)
No patches required.
  
Back to top

End of Support Life information

Last updated on 2024-04-19.  Refer to EOSL page for more information about support.
Release Date(GA)Extended Support StartsSustaining Support StartsEnd of Support Life Date(EOSL)
2015-07-052020-07-052022-07-31-
  
Back to top

Platform configuration

Tested and supported editions:
    Edition Version Notes
    Windows Server 2012 R2 Standard, Datacenter and Storage Edition GA  The support for Windows Server 2012 R2 Standard and Datacenter includes Server Core versions.
    VCS agent for MSMQ is not supported on Windows Server 2012 R2, therefore neither is clustering EV for this platform.

Compatible and supported editions, but not tested by Veritas:
    Edition Version Notes
    Windows Server 2012 R2 Essentials, and Foundation Edition GA  VCS agent for MSMQ is not supported on Windows Server 2012 R2, therefore neither is clustering EV for this platform.

Related documentation
  
Back to top

Host bus adapter (HBA) parameters and switch parameters

Unless otherwise stated in the hardware compatibility list (HCL), the specified Veritas product supports all fibre channel and iSCSI HBAs and fibre channel switches supported by the platform and storage array manufacturers. For more details, click the link to the HCL.
HBA Support:
    OS HBA model iSCSI software initiator version
    Microsoft Windows Microsoft iSCSI Software Initiator [1] 2.07 or above

    Note 1: The Microsoft iSCSI Software Initiator is supported on any Ethernet NIC card that is supported by the Microsoft iSCSI Software Initiator. In general, the Microsoft iSCSI initiator version listed on the HCL has been tested and qualified at the time of the SFW HA release. However, Veritas will support customers utilizing a newer version. Check with Microsoft on the most current and supported release of the iSCSI initiator. Recommended Microsoft iSCSI Software Initiator setting for adding a new target is to specifically select the adapter and port of the NIC configured for the iSCSI connection instead of selecting the default adapter. There is no DMP support for the Microsoft iSCSI Software Initiator unless an MPIO DSM is available for the specific array.

  
Back to top

Operations Manager

Veritas InfoScale Operations Manager gives you a single, centralized management console for the InfoScale products. You can use it to monitor, visualize, and manage storage and cluster resources, and generate reports about these components in the Management Server domain.It can also help administrators centrally manage diverse data center environments. This section lists the documents for Veritas InfoScale Operations Manager 8.0.2.
Documentation
  
Back to top

Array parameters

Dell EMC 
    ArrayModeInterfaceNote
    Celerra seriesA/A-AFibre Channel 
    Celerra seriesA/P-CFibre Channel 
    CLARiiON AX seriesA/A-AFibre Channel* Supports CLARiiON AX4 only.
    CLARiiON AX seriesA/A-AiSCSI* Supports CLARiiON AX4 only.
    CLARiiON AX series with PowerPathA/A-AFibre Channel* Supports CLARiiON AX4 only.
    CLARiiON AX series with PowerPathA/A-AiSCSI* Supports CLARiiON AX4 only.
    CLARiiON AX seriesA/P-CFibre Channel* Supports CLARiiON AX4 only.
    CLARiiON AX seriesA/P-CiSCSI* Supports CLARiiON AX4 only.
    CLARiiON AX series with PowerPathA/P-CFibre Channel* Supports CLARiiON AX4 only.
    CLARiiON AX series with PowerPathA/P-CiSCSI* Supports CLARiiON AX4 only.
    CLARiiON CX3 seriesA/A-AFibre Channel 
    CLARiiON CX3 seriesA/A-AiSCSI 
    CLARiiON CX3 series with PowerPathA/A-AFibre Channel 
    CLARiiON CX3 series with PowerPathA/A-AiSCSI 
    CLARiiON CX3 seriesA/P-CFibre Channel 
    CLARiiON CX3 seriesA/P-CiSCSI 
    CLARiiON CX3 series with PowerPathA/P-CFibre Channel 
    CLARiiON CX3 series with PowerPathA/P-CiSCSI 
    CLARiiON CX4 seriesA/A-AFibre Channel 
    CLARiiON CX4 seriesA/A-AiSCSI 
    CLARiiON CX4 series with PowerPathA/A-AFibre Channel 
    CLARiiON CX4 series with PowerPathA/A-AiSCSI 
    CLARiiON CX4 seriesA/P-CFibre Channel 
    CLARiiON CX4 seriesA/P-CiSCSI 
    CLARiiON CX4 series with PowerPathA/P-CFibre Channel 
    CLARiiON CX4 series with PowerPathA/P-CiSCSI 
    EqualLogic PS5000 seriesA/AiSCSI* There is a known problem of IO hang sometimes when a NIC port is disabled on the Switch. Also, it is recommended to use 2 NICs for private heartbeat and a separate NIC for public-mix use or client-only use in MSCS environments due to a known issue when Private NICs are used for private heartbeat and other types of traffic.
    EqualLogic PS6000 seriesA/AiSCSI 
    PowerVault MD32xx SeriesA/P-CiSCSI 
    PowerVault MD32xx SeriesA/P-CSAS 
    PowerVault MD36xx SeriesA/P-CFibre Channel 
    PowerVault MD36xx SeriesA/P-CiSCSI 
    PowerVault MD38xx SeriesA/P-CFibre Channel* Requires Hotfix_7_0_16101_129_3889098 or higher for VDID or Enclosure discovery.
    SC SeriesA/AFibre Channel* Support Storage Center OS (SCOS) software version 6.2.2 and higher.
    SC SeriesA/AiSCSI* Support Storage Center OS (SCOS) software version 6.2.2 and higher.
    Symmetrix DMX seriesA/AFibre Channel* Requires firmware version 5670.73 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * Supports Symmetrix DMX-3 and Symmetrix DMX-4 only.
    Symmetrix DMX series with PowerPathA/AFibre Channel* Supports Symmetrix DMX-3 and Symmetrix DMX-4 only.
    Symmetrix VMAX seriesA/AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    Symmetrix VMAX series with PowerPathA/AFibre Channel 
    VMAX3/VMAX All Flash Family seriesA/AFibre Channel 
    VNX seriesA/A-AFibre Channel* Supported with block mode storage only.
    VNX seriesA/A-AiSCSI* Supported with block mode storage only.
    VNX series with PowerPathA/A-AFibre Channel 
    VNX seriesA/P-CFibre Channel* Supported with block mode storage only.
    VNX seriesA/P-CiSCSI* Supported with block mode storage only.
    VNX series with PowerPathA/P-CFibre Channel 
    VNX2 seriesA/A-AFibre Channel* Supported with block mode storage only.
    VNX2 series with PowerPathA/A-AFibre Channel 
    VNX2e seriesA/A-AFibre Channel 
    VPLEXA/AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    VPLEX with PowerPathA/AFibre Channel 
    XtremIOA/AFibre Channel 
Fujitsu 
    ArrayModeInterfaceNote
    ETERNUS DX400/DX500/DX600 seriesA/AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS DX400/DX500/DX600 seriesA/A-AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS DX60/DX80/DX90/DX100/DX200 seriesA/AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    * Thin Reclamation is not supported with ETERNUS DX60/DX60 S2/DX80/DX90.
    ETERNUS DX60/DX80/DX90/DX100/DX200 seriesA/A-AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    * Thin Reclamation is not supported with ETERNUS DX60/DX60 S2/DX80/DX90.
    ETERNUS DX8000 S3/S4 seriesA/AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS DX8000 S3/S4 seriesA/A-AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS DX8000 seriesA/AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS DX8000 seriesA/A-AFibre Channel* Ensure proper array settings are configured to support this mode.
    * Fujitsu Storage Cluster is not supported.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS VS850A/A-AFibre Channel 
    ETERNUS VS850 with Subsystem Device DriverA/A-AFibre Channel 
    ETERNUS2000 seriesA/AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    ETERNUS4000 seriesA/AFibre Channel* Excludes ETERNUS4000 models 80 and 100.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
    ETERNUS8000 seriesA/AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details.
Hewlett Packard Enterprise 
    ArrayModeInterfaceNote
    2000 G2 seriesA/A-AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    2000 G2 seriesA/A-AiSCSI* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    2000 G2 seriesA/A-ASAS* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    3PAR F/T-Class, StoreServ 7000/8000/9000/10000/20000 StorageA/AFibre Channel* 3PAR F/T-Class maximum firmware version is 3.1.3; 3PAR StoreServ 7000/10000 minimum firmware version 3.1.2 and StoreServ 8000/20000 minimum firmware version 3.2.2 are required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * StoreServ 8000/20000 minimum firmware version 3.2.2 MU1 is required for Thin Reclamation support.
    Alletra 6000 SeriesA/A-AFibre Channel 
    Alletra 9000 StorageA/AFibre Channel 
    EVA4100/6100/8100A/A-AFibre Channel* Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * When utilizing the HP EVA arrays with SFW DMP, iSCSI is supported when used with the HP EVA iSCSI Connectivity Option. However, Active/Active Load Balancing algorithms are not supported in this configuration because SCSI-3 Persistent Reservation is not supported with the EVA iSCSI Connectivity Option at this point in time. Therefore, SCSI-3 support cannot be used and must be disabled in the system registry or system wide in the Veritas Enterprise Administrator (VEA) Control Panel System Settings when the EVA iSCSI Connectivity Option, by itself or in combination with other arrays, is connected to a host.
    EVA4100/6100/8100A/A-AiSCSI* Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * When utilizing the HP EVA arrays with SFW DMP, iSCSI is supported when used with the HP EVA iSCSI Connectivity Option. However, Active/Active Load Balancing algorithms are not supported in this configuration because SCSI-3 Persistent Reservation is not supported with the EVA iSCSI Connectivity Option at this point in time. Therefore, SCSI-3 support cannot be used and must be disabled in the system registry or system wide in the Veritas Enterprise Administrator (VEA) Control Panel System Settings when the EVA iSCSI Connectivity Option, by itself or in combination with other arrays, is connected to a host.
    EVA4400/6400/8400 seriesA/A-AFibre Channel* Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    MSA 1040 SANA/A-AFibre Channel 
    MSA 2040 SANA/A-AFibre Channel 
    MSA 2040 SANA/A-AiSCSI 
    MSA 2040 SANA/A-ASAS 
    MSA P2000A/A-AFibre Channel 
    MSA1000A/AFibre Channel 
    MSA1500A/AFibre Channel* Active/Active array firmware is required. Contact your local HP representative for more information.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    MSA2000fc seriesA/AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    MSA2012iA/AiSCSI* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    MSA2012saA/ASAS* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    MSA2212iA/AiSCSI 
    MSA2212saA/ASAS 
    P2000 G3 MSA seriesA/A-AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There is a known issue with support for HP P2000 G3 MSA series arrays where disabling all but 1 active path to the lun causes disk missing from the server.
    P2000 G3 MSA seriesA/A-AiSCSI* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There is a known issue with support for HP P2000 G3 MSA series arrays where disabling all but 1 active path to the lun causes disk missing from the server.
    P2000 G3 MSA seriesA/A-ASAS* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    * There is a known issue with support for HP P2000 G3 MSA series arrays where disabling all but 1 active path to the lun causes disk missing from the server.
    P6000 EVA seriesA/A-AFCoE* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    P6000 EVA seriesA/A-AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    P6000 EVA seriesA/A-AiSCSI* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    P9500A/AFibre Channel* Requires firmware version 70-01-04-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    XP10000/12000A/AFibre Channel* Requires firmware version 50-01-40-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    XP20000/24000A/AFibre Channel 
    XP7 seriesA/AFibre Channel 
Hitachi Vantara 
    ArrayModeInterfaceNote
    AMS/WMS seriesA/P-CFibre Channel 
    HUS 100 seriesA/AFibre Channel 
    HUS 100 series with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    HUS VMA/AFibre Channel 
    HUS VM with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    SMS/AMS2000 seriesA/AFibre Channel* Excludes SMS100.
    * SMS does not support Thin Provisioning.
    SMS/AMS2000 seriesA/AiSCSI* Excludes SMS100.
    * SMS does not support Thin Provisioning.
    SMS/AMS2000 series with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel* Excludes SMS100.
    SMS/AMS2000 series with HDLM (Hitachi Dynamic Link Manager)A/AiSCSI* Excludes SMS100.
    Thunder 9500V seriesA/P-CFibre Channel 
    Thunder 9500V series with HDLM (Hitachi Dynamic Link Manager)A/P-CFibre Channel 
    USP/NSC seriesA/AFibre Channel* Requires firmware version 50-05-22-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    USP/NSC series with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    USPV/USPVMA/AFibre Channel 
    USPV/USPVM with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    VSPA/AFibre Channel* Requires firmware version 70-01-04-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    VSP with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    VSP G seriesA/AFibre Channel 
    VSP G series with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    VSP Gx00/Fx00 seriesA/AFibre Channel 
Huawei 
    ArrayModeInterfaceNote
    18000 seriesA/AFibre Channel* For Huawei 18000 A/A, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB.
    OceanStor SeriesA/A-AFibre Channel* For OceanStor V3 models, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB.
    * Thin Reclamation is only supported with OceanStor Series with volumes track aligned to 2048 sectors, the ALUA explicit trespass on Thin LUN is not supported.
    OceanStor SeriesA/A-AiSCSI* For OceanStor V3 models, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB.
    * Thin Reclamation is only supported with OceanStor Series with volumes track aligned to 2048 sectors, the ALUA explicit trespass on Thin LUN is not supported.
    S5000 seriesA/P-CFibre Channel 
    VIS seriesA/AFibre Channel 
IBM 
    ArrayModeInterfaceNote
    DS3950A/P-CFibre Channel* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    DS3950 with DS Storage ManagerA/P-CFibre Channel 
    DS5020A/P-CFibre Channel* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    DS5020 with DS Storage ManagerA/P-CFibre Channel 
    FlashSystem seriesA/AFibre Channel* Supports FlashSystem 840/900 models.
    Spectrum Virtualize seriesA/A-AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    Spectrum Virtualize seriesA/A-AiSCSI* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    Spectrum Virtualize series with Subsystem Device DriverA/A-AFibre Channel 
    Storwize seriesA/A-AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    Storwize seriesA/A-AiSCSI* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    Storwize series with Subsystem Device DriverA/A-AFibre Channel 
    System Storage DS3000 seriesA/P-CFibre Channel* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS3000 seriesA/P-CiSCSI* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS3000 seriesA/P-CSAS* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS3500 seriesA/P-CFibre Channel* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS3500 seriesA/P-CiSCSI* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS3500 seriesA/P-CSAS* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS5000 seriesA/P-CFibre Channel* IMPORTANT: These arrays require additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use any of these arrays with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required.
    * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS5000 series with DS Storage ManagerA/P-CFibre Channel 
    System Storage DS6000 seriesA/A-AFibre Channel* Requires firmware version 6.1.600.46 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS6000 series with Subsystem Device DriverA/A-AFibre Channel 
    System Storage DS8000 seriesA/AFibre Channel* Requires firmware version 6.1.600.46 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage DS8000 series with Subsystem Device DriverA/AFibre Channel 
    System Storage N seriesA/A-AFibre Channel* Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage N seriesA/A-AiSCSI* Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage N seriesA/P-CFibre Channel* Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage N seriesA/P-CiSCSI* Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    System Storage XIV seriesA/AFibre Channel* Excludes A9000 & A9000R models.
    * To obtain Clustering support with IBM XIV, a minimum Firmware level of 10.0.1.c is required.
Imation 
    ArrayModeInterfaceNote
    Nexsan E-Series SystemsA/AFibre Channel 
Infinidat 
    ArrayModeInterfaceNote
    InfiniBox F-SeriesA/AFibre Channel 
Intel 
    ArrayModeInterfaceNote
    DC P3700A/APCIe 
    SSD 910A/APCIe 
Kaminario 
    ArrayModeInterfaceNote
    K2A/AFibre Channel 
NetApp 
    ArrayModeInterfaceNote
    AFF SeriesA/A-AFibre Channel* A minimum version of ONTAP 8.3 is required to support this array.
    AFF SeriesA/A-AiSCSI* A minimum version of ONTAP 8.3 is required to support this array.
    FAS2000/FAS900/FAS200 seriesA/A-AFibre Channel* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS2000/FAS900/FAS200 seriesA/A-AiSCSI* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS2000/FAS900/FAS200 seriesA/P-CFibre Channel 
    FAS2000/FAS900/FAS200 seriesA/P-CiSCSI 
    FAS3000/V3000 seriesA/A-AFibre Channel* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS3000/V3000 seriesA/A-AiSCSI* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS3000/V3000 seriesA/P-CFibre Channel 
    FAS3000/V3000 seriesA/P-CiSCSI 
    FAS6000/V6000 seriesA/A-AFibre Channel* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS6000/V6000 seriesA/A-AiSCSI* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS6000/V6000 seriesA/P-CFibre Channel 
    FAS6000/V6000 seriesA/P-CiSCSI 
    FAS8000/FAS9000 SeriesA/A-AFibre Channel* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS8000/FAS9000 SeriesA/A-AiSCSI* InfoScale Foundation 7.0 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only.
    FAS8000/FAS9000 SeriesA/P-CFibre Channel 
    FAS8000/FAS9000 SeriesA/P-CiSCSI 
Nexenta 
    ArrayModeInterfaceNote
    NexentaStorA/A-AFibre Channel 
Nexsan 
    ArrayModeInterfaceNote
    Beast SystemsA/AFibre Channel 
NimbleStorage 
    ArrayModeInterfaceNote
    CS/AF/HF-SeriesA/P-CFibre Channel 
Oracle 
    ArrayModeInterfaceNote
    Axiom seriesA/A-AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    FS1-2A/A-AFibre Channel 
    Storage 6580/6780 seriesA/P-CFibre Channel 
    StorageTek 2500 seriesA/P-CFibre Channel 
    StorageTek 2500 seriesA/P-CiSCSI 
    StorageTek 2500 seriesA/P-CSAS 
    StorageTek 6140 arrayA/P-CFibre Channel 
    StorageTek 9900 seriesA/AFibre Channel 
    StorageTek 9900 series with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    StorageTek 9985/9990 seriesA/AFibre Channel 
    StorageTek 9985/9990 series with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    StorageTek 9985V systemA/AFibre Channel 
    StorageTek 9985V system with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    StorageTek 9990V systemA/AFibre Channel 
    StorageTek 9990V system with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
    Sun Storage 6180 arrayA/P-CFibre Channel 
    ZFS Storage Appliance seriesA/A-AFibre Channel* Excludes ZFS Storage ZS4-4.
    ZFS Storage Appliance seriesA/A-AiSCSI* Excludes ZFS Storage ZS4-4.
Pure Storage 
    ArrayModeInterfaceNote
    FlashArray seriesA/AFibre Channel 
SanDisk 
    ArrayModeInterfaceNote
    ioDriveA/APCIe 
    ioDrive2A/APCIe 
    ioMemory PX600 seriesA/APCIe* Patch is required, see https://sort.veritas.com/patch/detail/11066 for details.
    ioMemory SX300 seriesA/APCIe* Patch is required, see https://sort.veritas.com/patch/detail/11066 for details.
StorageTek 
    ArrayModeInterfaceNote
    FlexLine 200/300 seriesA/P-CFibre Channel* Support for the StorageTek Flexline 300 series Storage Systems includes the FLX380 array only.
Sun 
    ArrayModeInterfaceNote
    StorageTek 6130A/P-CFibre Channel* The Sun StorEdge 6130 array requires additional configuration steps in order to work properly with Veritas InfoScale Foundation for Windows. Before attempting to use the Sun StorEdge 6130 array with Veritas InfoScale Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP. Specific firmware levels from the manufacturer for these arrays may also be required.
    StorageTek 6540A/P-CFibre Channel 
    StorEdge 9910/9960A/AFibre Channel* Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array.
    StorEdge 9910/9960 with HDLM (Hitachi Dynamic Link Manager)A/AFibre Channel 
Violin Memory 
    ArrayModeInterfaceNote
    Violin 3000/6000 seriesA/AFibre Channel 
    Violin 3000/6000 seriesA/A-AFibre Channel* A minimum array firmware version G5.5.1 is required to support ALUA mode.